// NEXT-GEN SERVER PROCESSORS — COMPUTE 2026

128 cores of raw compute. Zero compromise.

The Nimbus X9 pairs 128 compute cores with 9.8 TFLOPS of vector throughput and a 5.0 GT/s coherent fabric — inside a 350 W envelope engineered for the AI-first data center.

  • 128 coresCORES / SOCKET
  • 9.8 TFLOPS peak vector throughputPEAK TFLOPS
  • 5.0 gigatransfers per second fabric linkFABRIC LINK
  • 2.1 times performance per wattPERF / WATT

// MODULES — X9 ARCHITECTURE

Engineered as modules, not monoliths

Every subsystem is isolated, instrumented, and hot-swappable in software — profile compute, power, and fabric independently.

// MODULE 01 — COMPUTE

Raw throughput

9.8 TFLOPS per socket from 512-bit vector units and a branch predictor trained on real HPC traces. Sustained clocks hold within 3% of peak across 72-hour runs — no thermal cliff, no silent throttling.

// MODULE 02 — POWER

Efficiency by design

Adaptive clock domains park idle cores in under 40 ns and re-boost them just as fast. At 40% load the X9 still runs at 82% efficiency — the same rack envelope now holds 2.1× the usable FLOPS.

// MODULE 03 — FABRIC

Scale without limits

A 5.0 GT/s coherent fabric stitches 4,096 sockets into one system image with sub-microsecond latency. ECC covers every hop, and failed links re-route around faults faster than a scheduler can notice.

// PIPELINE — DEPLOYMENT

From pallet to petaflop in three steps

No cabling spreadsheets, no week-long burn-in. The fabric does the topology; you do the science.

Deploy

X9 sleds slide into standard 19-inch racks — tool-less, with auto-negotiating fabric links. Rack, power, and walk away.

Orchestrate

The Nimbus controller discovers every socket, maps coherence domains, and exposes the fleet as a single scheduler endpoint in under 60 seconds.

Scale

Add sleds under load. Thermal and workloads re-route across the fabric in real time — 2 to 2,048 nodes with zero reboots.

// FIELD REPORTS

Operators who moved to X9

“We cut inference cost per token by 38% in the first week on X9 clusters. The fabric is the real story — east-west latency simply disappears.”

Dr. Lena VossDIRECTOR OF HPC · MERIDIAN LABS

“2,048 nodes, one system image, zero unplanned reboots in 14 months. Our previous fleet couldn’t survive a single firmware update.”

Marcus ChenCTO · FROSTLINE CLOUD

“Perf-per-watt closed the deal. We fit 40% more compute into the same power envelope, and the PUE curve followed it down.”

Amara OkaforVP INFRASTRUCTURE · NORTHGRID SYSTEMS

// PROCUREMENT

Pick your deployment class

Every tier ships with next-business-day replacement in year one. Volume terms available from 16 nodes up.

// TIER 01

Single Node

$1,890 /SOCKET

per socket · 1-year NBD warranty

  • 1× X9 socket — 128 cores
  • 5.0 GT/s fabric port
  • Standard firmware channel
  • Community forum support
  • Dedicated deployment engineer
  • 24/7 priority SLA
MOST POPULAR // TIER 02

Cluster

$7,900 /NODE

per dual-socket node · 3-year warranty

  • 2× X9 sockets — 256 cores
  • Redundant fabric links
  • Nimbus orchestration controller
  • 24/7 priority SLA
  • Dedicated deployment engineer
  • Custom TDP binning
// TIER 03

Data Center

CUSTOM

volume licensing · negotiated SLA

  • Fleet-wide fabric licensing
  • Custom TDP binning
  • On-site thermal audit
  • Named solutions architect
  • 99.99% uptime SLA
  • Single-unit retail orders

// SPEC SHEET — Q&A

Frequently asked questions

How does the X9 compare to the previous generation?

On HPL and Llama-class inference benchmarks the X9 delivers 2.1× the performance per watt of the X7. Per-core thermal telemetry re-allocates the heat budget every 40 ns, so sustained clocks stay within 3% of peak across 72-hour runs.

Which socket, OS, and software stacks are supported?

The X9 uses the LGA-N9 socket. Linux kernels 6.x and newer are supported day one, with first-class integration in Kubernetes and Slurm schedulers. GPU and TPU accelerators attach over the 5.0 GT/s fabric without host-bus bottlenecks.

What are the power and cooling requirements?

TDP is 350 W per socket. Standard sleds are air-cooled up to a 35 °C inlet; liquid-cooled sleds unlock full boost in dense 1U racks. Per-core power telemetry streams to the orchestration controller in real time.

What support and warranty coverage is included?

All tiers include next-business-day replacement for the first year. Cluster and Data Center plans add a 24/7 priority SLA, signed firmware delta channels, and a named deployment engineer for the life of the fleet.

How quickly can we deploy a pilot cluster?

Sleds ship in 2–4 weeks. A 16-node pilot — racked, orchestrated, and running your first workload — is typically online in under a single business day.

// EARLY ACCESS — WAVE 03

Put the X9 to work.

Join the 2026 early-access program. Silicon, sleds, and orchestration — bundled for pilot clusters, deployed in a day.

NO SPAM · UNSUBSCRIBE ANYTIME · HPC TEAMS ONLY